Opens in a new tab
NTP Clock Server Manufacturer in China
Technology / NTP hierarchy

Stratum 1 vs Stratum 2 NTP Servers

The number tells you where a server gets its time. Use that relationship to choose its role in your network.

What is the difference?

A Stratum 1 NTP server synchronizes directly to a reference clock. A Stratum 2 NTP server obtains time over NTP from a Stratum 1 server. Both can serve downstream clients. The distinction describes their place in the timing hierarchy; it does not assign a guaranteed accuracy to either server. [1]

For system integrators and IT teams evaluating the source behind a time service.

01 / Read the relationship

Two positions in the same timing chain.

Think of stratum as a count of timing levels back toward the reference. It counts NTP synchronization relationships, not the switches or routers crossed by a packet. [2]

Reference relationships and their practical implications. [1]
QuestionStratum 1Stratum 2
Where does time come from?A directly connected reference clock.An upstream Stratum 1 NTP server.
What is an example?A server using its local GNSS timing receiver.A distribution server synchronized over the LAN to that primary server.
What must the design provide?A suitable reference and its installation conditions.A usable upstream time service and an approved network path to it.
Can it serve clients?Yes, including downstream NTP servers.Yes, while also acting as an upstream server's client.
Is accuracy fixed by the number?No. Stratum 1 alone is not a performance specification.No. Stratum 2 alone is not a performance specification.

Keep the accuracy question separate.

A local Stratum 2 service may deliver better client results than a remote Stratum 1 service reached over a less predictable path. This is a possible outcome, not a ranking rule: the reference, implementation and network conditions still matter. [6]

Read NTP Server Accuracy: What to Measure and Where

02 / Follow the source

One primary source. Two distribution paths.

In this example, Server A uses a local reference. Some devices use A directly; others use Server B, which synchronizes to A and serves its own clients.

Reference level / conventionally Stratum 0

GNSS timing receiver

Local reference for Server A

Stratum 1

Server A · Primary server

Uses the reference directly

Direct client path

Client group A

Selected NTP source: Server A

Network transit devices do not add a timing level merely by carrying these packets.

Stratum 2

Server B · Distribution server

Uses A, then serves other devices

Downstream client path

Client group B

Selected NTP source: Server B

Figure 1. Original hierarchy example. Arrows show timing dependency, not one-way packet flow. The reference may be inside Server A. The two branches share A and its reference; they are not independent sources. [2]

Adding Server B creates another NTP level. Adding an ordinary switch between A and B does not. A device counts as another timing level only when it synchronizes a clock and provides a downstream time service, rather than simply forwarding traffic.

“Stratum 0” is not a better NTP server to query.

Reference clocks are conventionally shown at level 0 in hierarchy diagrams. In an NTP packet, however, a stratum field of 0 means unspecified or invalid; it is also used for special Kiss-o'-Death responses. Stratum 16 denotes an unsynchronized state. Neither is a normal synchronized server tier above Stratum 1. [3]

03 / Verify the active role

How to tell which stratum you are looking at.

A model description tells you what a device supports. Its current source and status tell you the role it is actually performing. Use the server interface or the documentation for the installed NTP implementation.

  1. Identify whose number is displayed.

    A source list can show the upstream server's stratum, while a local status report shows the device's own stratum. For example, chrony's sources report describes its sources; tracking describes the local system. These numbers need not match. [4]

  2. Find the source currently selected.

    Read the active reference or selected-source indicator. An address being configured or reachable does not establish that it is being used for synchronization. Record the selected source alongside the number. [4]

  3. Trace the chain one level upstream.

    Does the server use a local reference, or another NTP server? In a normal synchronized chain, a server following a Stratum 1 source operates at Stratum 2; following a Stratum 2 source places it at Stratum 3. Verify the upstream relationship rather than inferring it from an enclosure or antenna connector. [2]

  4. Check the state behind the label.

    Confirm synchronization status and whether a local-reference or fallback mode is active. Some implementations can advertise a configured stratum without a current external reference. A low number alone therefore does not prove that the clock is correct. [5]

Illustrative status interpretation for a normal synchronized chain; not captured product output.
Device being checkedSelected sourceSource stratumDevice's own stratum
Server BServer A12
A client using BServer B23, where the client reports its local stratum

A client reporting local Stratum 3 has not become a time service for other devices. Serving downstream clients is a separate function and configuration. [3]

04 / Apply it to selection

Choose where the reference belongs.

Start by asking whether this location should establish the reference for the network or distribute an existing time service. That decision gives the stratum requirement a practical purpose.

A local reference is required

Evaluate a Stratum 1 role.

This fits a site expected to obtain reference time directly, rather than rely on an upstream NTP service. Confirm that the proposed reference can be installed and maintained there. For a GNSS-based arrangement, reception is part of that decision.

Question to resolve: Who will provide and maintain the reference used by this server?

An approved primary service exists

Evaluate a Stratum 2 role.

A downstream server can use an existing Stratum 1 service and provide an access point for its client group. Assess the upstream service and permitted path together. A private LAN source is entirely possible; Stratum 2 does not mean public internet time.

Question to resolve: Which primary service will this server use, and can that dependency meet the site's needs?

The two roles can coexist, as Figure 1 shows. A distribution layer gives you another service to manage and another upstream dependency to document. Specify that role deliberately, then check the required hardware and configuration.

Do not select a source using only the lowest number.

Client selection depends on the implementation, configuration and source condition. For example, chrony evaluates synchronization distance and applies a configurable stratum weighting. It does not simply accept every Stratum 1 source ahead of every Stratum 2 source. [5]

Related questions

Read the role without adding assumptions.

Does Stratum 2 mean a backup server?

No. “Secondary” describes a server that takes time from an upstream NTP server. It may serve clients continuously as their normal time source. Standby operation and failover require their own design; the stratum number does not specify them. [3]

Does every Stratum 1 server use GPS?

No. GPS/GNSS is one reference option. The defining relationship is direct synchronization to a reference clock; the stratum number does not identify the satellite system or the supported input hardware. Check the actual reference and device configuration. [3]

Can the same server operate at a different stratum?

Yes, where its hardware and software support the relevant sources. A server using a direct reference can operate at Stratum 1; if it instead synchronizes over NTP to a Stratum 1 server, its normal role is Stratum 2. Changing an advertised number alone does not change its reference quality. [1] [5]

Continue your evaluation

Turn the timing role into a clear requirement.

Performance

Define what accuracy means.

Keep the measurement point and conditions separate from the server's stratum.

Read the NTP server accuracy guide
Specification

Build the wider requirement.

Connect the reference role to the interfaces, installation and service needs of your project.

Review the available server configurations
Available hardware

Compare server models.

Use the product comparison to shortlist hardware, then confirm the source configuration for the intended role.

Compare NTP Servers