HCE208 NTP Clock Server
One NTP port. Optional isolated dual interfaces.
HCE208 combines a single 10/100 Mbps NTP connection with serial time-code and 1PPS outputs. Specify the 2N option for two physically isolated timing ports, add an OCXO if required, or select the DC-powered Mini enclosure.

Start with the connection layout.
The rackmount HCE208 starts with a defined set of timing connections. Its ordering options let you change the port arrangement or add a dedicated holdover oscillator without treating every configuration as the same unit.
Identify the service port
LAN1 is the NTP Ethernet connection. The separate RJ45 CONSOLE socket carries RS232 management signals; it is not an additional network timing port.
Specify physical separation
The 2N configuration provides two physically isolated NTP Ethernet ports. Include that code when the port separation requirement forms part of the purchase specification.
Choose the enclosure first
Select the 1U version for rack installation, or request the HCE208-GN-Mini for a DC-powered desktop unit. Check the Mini drawing and supply requirements independently of the rackmount data.
Choose your configuration.
Use the examples below to distinguish the base receiver configuration, the OCXO/dual-port build and the desktop variant. The expanded tables retain the complete HCE208 model list.
HCE208-GN-O-2N
Adds an OCXO and two physically isolated NTP ports to the GPS/BeiDou rackmount configuration for operation during short reference interruptions.
Discuss this configuration →HCE208-GN-Mini
DC-powered HCE208 with GPS/BeiDou reception in a desktop enclosure. Verify the Mini interface set when ordering.
Discuss this configuration →Ordering codes & option selection
Build the HCE208 ordering reference from the relevant code groups. For example, O identifies the oscillator option and 2N identifies isolated dual network ports. Have the final combination checked before placing an order.
Reference source
| Code | Reference |
|---|---|
| GP | GPS |
| BD | BeiDou |
| GN | BeiDou + GPS |
| BD3 | BeiDou-3 |
| CDMA | CDMA |
| PTP | PTP / IEEE 1588v2 |
| TOD | 1PPS + TOD |
| BDC | IRIG-B input at RS422 level |
| N | No reference source by default |
Holdover clock
| Code | Clock |
|---|---|
| O | Crystal oscillator (the specified option is an OCXO) |
| N | No dedicated holdover clock unit by default |
Power
| Code | Power option |
|---|---|
| Default | 220 V single power supply |
| DC | DC input |
Output / interface options
| Code | Option |
|---|---|
| 2N | Dual physically isolated NTP Ethernet ports |
| PTP | PTP / IEEE 1588v2 |
| BDC | IRIG-B DC output |
| BAC | IRIG-B AC output |
| SQ | 10 MHz square-wave output |
| SIN | 10 MHz sine-wave output |
All listed model examples
| Model | Description |
|---|---|
| HCE208-GN | BeiDou/GPS — common model |
| HCE208-GN-O | BeiDou/GPS with OCXO — common model |
| HCE208-GN-2N | BeiDou/GPS with dual Ethernet ports — common model |
| HCE208-GN-O-2N | BeiDou/GPS with OCXO and dual Ethernet ports — common model |
| HCE208-GP | GPS only |
| HCE208-BD | BeiDou only |
| HCE208-CDMA | CDMA |
| HCE208-GN-O-N-BDC | BeiDou/GPS, OCXO and IRIG-B output |
| HCE208-N-O | Stratum 2 time server with OCXO |
| HCE208-GNJT* | GPS/BeiDou with AC/DC supply |
| HCE208-GNJT-2N* | GPS/BeiDou with AC/DC supply and dual Ethernet ports |
| HCE208-GN-Mini* | GPS/BeiDou desktop model with DC supply |
The HCE208 suffixes follow the source model list. Ask for clarification of starred variants and GN-O-N-BDC rather than inferring additional functions from the letters.
Specifications & interfaces.
HCE208 receiver, oscillator, signal and enclosure data are grouped below. Values for the standard rackmount unit do not automatically describe a Mini or an optional module.
01 Network protocols & timing performance
| Parameter | Specification |
|---|---|
| Time protocols | NTP v1/v2/v3/v4 (unicast, multicast, broadcast and Autokey); SNTP |
| Remote access / transfer | Telnet, SSH, FTP |
| Network management | SNMP v1/v2/v2c/v3; MIB II (RFC 1213) |
| IP support | IPv4, IPv6, IPv4/IPv6 hybrid mode |
| Parameter | Specification |
|---|---|
| Satellite-referenced synchronisation accuracy | <100 ns |
| NTP network synchronisation accuracy | 0.1–2 ms, typical on a local area network |
| Client capacity | >32,000 |
| NTP request capacity | >2,000 requests/s |
Assess the HCE208 NTP figures at the network client. The hardware and 1PPS values refer to other measurement points. The published capacity figures do not specify a polling interval or test load.
Additional performance figures in the source datasheet
| Parameter | Specification |
|---|---|
| Hardware synchronisation accuracy | <30 ns, typical RMS, using a BeiDou/GPS receiver |
| LAN NTP time-service accuracy | <0.1 ms, using a BeiDou/GPS receiver |
| NTP accuracy on complex networks | <10 ms |
| NTP requests per port | >2,000 requests/s |
| Time-synchronisation clients | >30,000 |
| Daily average frequency accuracy | <1 × 10⁻¹² |
| MTBF | >80,000 h |
Two LAN figures appear in the HCE208 source: <0.1 ms in the feature list and 0.1–2 ms typical in the detailed specifications. Hardware synchronisation is listed as <30 ns typical RMS, while satellite-referenced synchronisation is <100 ns. Obtain the relevant test conditions before using a figure as an acceptance limit.
02 Satellite receivers
| Receiver | Signal band | Channels | Cold start | Hot start | Reacquisition | Timing accuracy | Position accuracy |
|---|---|---|---|---|---|---|---|
| GPS receiver | L1 | 32 | 35 s | 1 s | 1 s | 30 ns | 2 m |
| BeiDou receiver | B1I | 32 | 35 s | 1 s | 1 s | 30 ns | 2 m |
| BeiDou/GPS receiver | L1, B1I | 32 | 35 s | 1 s | 1 s | 30 ns | 2 m |
| BeiDou-3/GPS receiver | L1, B1I, B1C | 40 | 35 s | 1 s | 1 s | 30 ns | 2 m |
The BeiDou/GPS timing receiver can be configured to use BeiDou alone, GPS alone, or both constellations together.
03 Optional clock & holdover specifications
| Clock parameter | OCXO |
|---|---|
| Average frequency accuracy | <1 × 10⁻¹² / 24 h |
| Frequency stability | <5 × 10⁻¹² / s |
| Daily ageing rate | <5 × 10⁻¹⁰ |
| Phase noise | ≤−155 dBc/Hz at 10 kHz |
| Holdover accuracy | <1 ms / 72 h |
The table describes the optional HCE208 OCXO. Its evaluation should state warm-up time, previous reference lock, ambient temperature and the interval over which holdover is measured.
04 Timing signals & optional modules
Standard 1PPS and serial outputs
| Parameter | Specification |
|---|---|
| 1PPS accuracy | Offset from standard UTC <30 ns RMS |
| 1PPS electrical characteristics | TTL level; rising edge; pulse width 100 ms |
| TOD serial output | RS232 level; 9600 baud; 8-N-1 |
Optional external reference inputs
| Parameter | Specification |
|---|---|
| 1PPS + TOD input | TOD complies with NMEA 0183. |
| IRIG-B input | RS422 level; complies with GJB 2991A-2008. |
| Mobile-network receiver | Supports CDMA/4G communication networks. |
| PTP input | Complies with IEEE 1588v2. |
Optional time and frequency outputs
| Parameter | Specification |
|---|---|
| IRIG-B output module | Complies with GJB 2991A-2008; DC output at TTL/RS422 levels; AC output, balanced or unbalanced, with a modulation amplitude ratio of 3:1. |
| PTP output module | Complies with IEEE 1588v2; supports Gigabit Ethernet / SFP+ optical ports, unicast/multicast, one-step/two-step modes and AI/SI/DI settings; up to 256 clients per PTP port. |
| 10 MHz square-wave output | LVTTL level; accuracy and stability follow the internal clock signal. |
| 10 MHz sine-wave output | 50 Ω impedance; output power >7 dBm; accuracy, stability and phase noise follow the internal clock signal. |
Other modules / interfaces
| Parameter | Specification |
|---|---|
| Dry-contact alarm | Terminal-block interface; supports loss-of-lock and fault alarms. |
The optional PTP description uses AI/SI/DI without defining those terms. Its SFP+ reference applies to that module; the HCE208 standard NTP interface remains 10/100 Mbps. Confirm the selected module and its connectors.
05 Physical & environmental specifications
| Parameter | Specification |
|---|---|
| Dimensions | 1U enclosure: 433 × 44.5 × 365 mm |
| Weight | <5 kg |
| Power input | 100–240 V AC |
| Operating temperature — main unit | −10 °C to +55 °C |
| Operating temperature — antenna | −40 °C to +75 °C |
| Storage temperature | −45 °C to +85 °C |
| Humidity | 95%, non-condensing |
| Power consumption | <25 W |
Use the ordered HCE208 variant’s drawing and electrical specification to check installation fit. The rackmount figures do not establish the Mini dimensions or DC-input rating.
06 Front & rear panels
- The HCE208 VFD presents time, reference-lock state, satellite count and position (latitude, longitude and altitude), together with interface IP addresses and operating status.
- Indicators show power status, satellite lock status, pulse-per-second status and equipment alarms.
| Interface | Description |
|---|---|
| ANT | 1 × BNC satellite antenna connector; 5 V feed |
| LAN1 | 1 × RJ45; 10/100 Mbps auto-negotiating Ethernet |
| CONSOLE | 1 × RJ45; RS232-level control terminal |
| TOD | 2 × DB9 female; RS232 level; time and position information |
| 1PPS | 1 × BNC; TTL level |
| Options | External reference inputs, PTP, 10 MHz and IRIG-B; contact sales for starred models and further details. |
07 Functions, management & software
Functions
- Default HCE208 operation is Stratum 1; configuration as Stratum 2 is also supported.
- MD5 authentication is available on HCE208.
- Configured source priorities govern automatic switching between supported references.
- The SNMP service allows a network-management system to monitor the unit.
- Additional input and output modules are selected for the specified equipment interfaces.
- Device administration includes logs and access through SSH, Telnet or CONSOLE.
SNTP synchronisation software
- The Windows SNTP utility updates the computer’s system clock.
- It can launch at startup and remain in the system tray.
- An interval setting controls recurring clock updates.
- Users can trigger an update manually.
The HCE208 summary names Windows, Linux, UNIX, Sun Solaris and IBM AIX as client-system families. Check the actual client implementation and version for the installation.
Certificate-based mechanisms are mentioned for HCE208 without implementation details. Request the relevant description if authentication is part of the specification.
08 Package contents & optional accessories
| Included item | Quantity / details |
|---|---|
| Main unit | 1 |
| High-sensitivity timing antenna with 30 m cable | 1 |
| Mounting bracket set | 1 set |
| 1 m power cable | 1 |
| 1.5 m control cable | 1 |
| Chinese-language user manual | 1 |
| Documentation disc | 1 — documentation, SNTP time-synchronisation software and equipment operating instructions |
Optional accessories
- Antenna feeder lightning arrester
- Special cable lengths: 50 m, 80 m or 100 m
- Ethernet digital slave clock
Check the HCE208 packing list against the chosen variant, especially the antenna cable, documentation format and supplied power lead.
Need more network connections?
If the required connection count exceeds the HCE208 options, compare this series with the six-port HCE210. The range page brings the differences together for a purchasing decision.
Clarify the exact build.
Why is the CONSOLE socket not a second NTP port?
LAN1 provides Ethernet time service. The RJ45 CONSOLE connector is an RS232 management interface, despite using the same connector shape. Specify a 2N model when two physically isolated NTP Ethernet ports are required.
How do HCE208-GN-O and HCE208-GN-2N differ?
The O suffix selects the dedicated OCXO; 2N selects dual isolated NTP ports. The listed HCE208-GN-O-2N configuration combines these two options.
Can I use the 1U dimensions for the Mini?
The 433 × 44.5 × 365 mm dimensions describe the rackmount enclosure. Request a Mini-specific drawing and DC-input specification before allocating space or selecting a supply.
Which serial and pulse connections are standard on the rackmount unit?
The base rackmount configuration provides two RS232 TOD ports and one TTL 1PPS output. The serial format is 9600 baud, 8-N-1. Refer to the signal table for pulse characteristics and connector details.
What should I check in the HCE208 accessory list?
The documented package includes a timing antenna with 30 m cable, mounting brackets and connection leads. Longer 50 m, 80 m and 100 m cable options and an antenna feeder lightning arrester are listed separately. Confirm the supplied items for the chosen variant.
Request an HCE208 build.
Send the HCE208 variant you are considering, or identify the port and enclosure choices still to be decided. We can discuss the exact ordering configuration.
- HCE208 suffixes, if already selected
- Rackmount or Mini enclosure and supply input
- Number of NTP ports and required signal outputs
- Unit quantity and delivery country
Please include HCE208 in your project message.
For a replacement unit, include a rear-panel photograph or the existing model code so the interfaces can be checked.